Sometimes a fixed dehumidification system does not meet situational requirements or pace of operations. Our line of highly mobile and customizable containerized mobile dehumidification systems ™ (CMS™) was developed to solve both issues.
The Dehumidified Container System (DCS™) family of products are Controlled Humidity Protection (CHP) envelopes that provides for a secure relocatable corrosion inhibiting and mold and mildew reducing environment for all types of gear and equipment.
The Containerized Mobile Operational Protection System™ (CMOPS™) is a highly portable dehumidification system for external applications like:
- Military Vehicle or Aircraft
- Multiple Containers
- Temporary Auxiliary or Emergency Space Dehumidification
- Any other field requirement location where low RH environments are needed
Dehumidified Container System (DCS™)
The system was built with modularity and customization in mind. The size of the container, the type of dehumidifier based on operating environment and controls are interchangeable to provide a solution for most user requirements.
Each self-contained DCS™ dehumidifier operates as a closed loop system, recirculating air to improve efficiency and reduce run-times. Set-points are user controlled to provide the best environment for the materials inside. Data-logging and trend chart options are available. Systems may be networked and remotely monitored for ease of operation confirmation and data retrieval.
Dehumidifier Containerized Storage Systems:
Stock 20′
- Door Options – One end, Both Ends, Center Open
- Normal Height or Hi-Cube
- Custom Paint Color
Stock 40′
- Door Options – One end, Both Ends, Center Open
- Normal Height or Hi-Cube
- Custom Paint Colors
Do It Yourself Conversion Kits are also available if you already have ISO or CONEX Containers.
Containerized Mobile Operational Protection System™ (CMOPS™)
The system is equipped to provide dehumidified air for the protection of external components, like vehicles, aircraft, containers of small building, tents or confined spaces.
The larger model supports up to 20 vehicles or 10 storage containers or a mix and match. It can also be used for auxiliary or emergency dehumidification for spaces up to 100K cubic feet. The quick-clamp ducting can be easily configured for multiple types of vehicles or flexible hoses and plenums are available for other equipment applications.
The CMOPS™ uses a standard 208 volt, 3 Phase, 73.4 FLA facility or expeditionary power source. Optional 208 VAC/ 1 phase, 230-240 VAC/ 3 phase and 460 VAC/ 3 phase.
All components like the dehumidifier, hard and flexible ducting, controls and optionally selectable vehicle, aircraft or container adapters are all contained within a single relocatable and securable 20′ ISO container.
Datalogging and Operating trend chart options are available. Systems may be networked and remotely monitored for ease of operation confirmation and data retrieval.
Features
- User Adjustable RH Control Zones
- Designed for Unattended Outdoor Operations
- Rapid Draw Down & Recovery to Proper Internal RH
- Secure Lockable Storage
- Low Energy Consumption
- Green Operation
- Energy Star Options
- Internal Operation Indicators Without Breaking Environmental Seal
- Door Mounted to Provide Maximum Loading Clearance and Storage Capacity
- Modular for Easy Upgrade or Repair
- Units Are Stackable (Front Needs Open Clearance for Access and Maintenance)
- Primary Components Made and Assembled in the USA
- Full Data Logging and Wired & Wireless Networking Available
- Low Maintenance
- Conversion Kits Available for Existing Container Retrofit
Container
ISO SIZE | External | Internal |
Unloaded |
Retrofit |
||||
Length | Width | Height | Length | Height | Width | |||
20″ | 20′ | 8′ | 8’6″ | 19’3″ | 7’8″ | 7’9″ | 5300 lbs | Yes |
40″ | 40′ | 8″ | 8’6″ | 39’5″ | 7″8″ | 7’9″ | 8400 lbs | Yes |
All specifications are close approximates due to manufacturing irregularities between manufacturers.
Other sizes, insulation, interior options and door configurations available.
Dehumidifier
Method | Blower |
Supply |
Amps | Other Information |
Refrigerant | 190 CFM @ 0.0 WG | 115v 1ph 60HZ | 5.1 | 70 pints per day removal at 80F and 60% RH. Optimum Operating Temp 33F – 100F. |
Desiccant | 52 CFM | 115v 1ph 60HZ | 6.4 | 18 pints per day removal at 80F and 60% RH. Optimum Operating Temp -4F – 105F |
Controls
Control |
On-Screen |
User |
Visual |
Trends |
Access |
Network |
Secure |
1 | No | Limited | No* | No | No | No | No |
2 | No | Yes | Yes | Yes | Limited | Limited | No |
3 | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
*Analog meter available
Other Options
- Maintenance and Service Contract (CLS)
- Filter and Spares Packages
- Local and Remote Access Control Alarming
- Wireless (Local Wi-Fi) and Cellular Monitoring and Reporting Services
- Custom Painting
- Other Container Customization
- Retrofit Installation
Ready for a customized dehumidification plan?
Ready for a customized dehumidification plan?
We would love to talk with you and understand your situation. We can work with you and your budget to conquer your moisture problems.
For questions or more information about controlling humidity for your application, please contact us at 800-974-9771, or fill out our form.